254-XZZ-M-04

Model 254 57.7-277V L-N (100-480V L-L) 0-1/0-5AAC 1P2W to 3P4W, Universal Programmable Transducer, 4 Configurable Outputs, 80-260V AC/DC Aux., Paladin Advantage, Crompton

1,007.00 1007.0 USD 1,007.00

1,007.00

  • Brand
  • Model
  • Input Range
  • Input Range
  • Input Range
  • Input Frequency
  • Input Frequency
  • Output
  • Output
  • Output
  • Output
  • Output
  • Output
  • Output
  • Aux. Power Supply
  • Aux. Power Supply
  • Tariff Code
  • ECCN

This combination does not exist.

PALADIN ADVANTAGE

UNIVERSAL PROGRAMMABLE TRANSDUCER

254-XZZ Datasheet 

TE Connectivity’s (TE) Crompton Instruments Paladin Advantage, 254-XZZ, is a programmable transducer which provides measurement isolation and conversion of all main electrical parameters into an industry standard DC output signal.  The 254-XZZ can be used in single and three-phase balanced or unbalanced three or four-wire electrical systems.  The 254-XZZ  as an accuracy of CL0.2 and includes RS485 Modbus RTU communications protocol and pulse/alarm output as standard. 


The 254-XZZ is an accurate device for the conversion of all main electrical parameters into a Voltage or mA output and provides measurement, isolation and conversion of up to four user defined inputs and outputs.  The device is supplied programmed to the users requirements but can be easily be reprogrammed to suit any application. 


Designed, developed and manufactured in the EU, with integrated microprocessor for exceptional waveform handling of distorted waveforms.  The 254-XZZ is ideal for low, medium and high voltage applications and provides a high protection against continuous and short circuit protection as well as galvanically isolated inputs and outputs.


The 254-XZZ-M-04 is supplied fully user configurable with up to 4 user defined inputs and outputs. It is possible to program the device as many times as required to suit any application.  TE supplies a free of charge software called the Paladin Tool, available for free download on the Crompton's website http://www.crompton-instruments.com/254-XZZ.html.  The Paladin Tool utility runs on a Personal Computer (PC) with Microsoft  windows Operating System.  The programmable transducer must be connected to the PC by a standard printer USB cable (not provided), and the auxiliary supply powered-on.


The USB connection to the transducer is fully isolated, allowing a safe programmability of the transducer itself even if it is completely wired to a live

system.


Key Features

  • DIN-rail enclosure

  • Measurement, isolation and conversion of up to 4 parameters

  • RS485 Modbus RTU protocol

  • Alarm/pulsed output

  • Programmable VT/CT ratio

  • True rms measurement

  • User programmable configuration

Benefits

  • Cost effective

  • CL 0.2 accuracy
  • Modbus communications
  • Fully Configurable

Applications

  • Motor control centers

  • Energy / Building management systems

  • Switchgear

  • Generator sets

Standards

  • IEC 61326

  • IEC 61010-1

  • IEC 62053-21
  • EN60688
  • RoHS Compliant

SPECIFICATION

Input
  • Nominal input voltage 57.7 V – 277 V AC L-N (100 – 480 V L-L) 480 V MAX

  • Max. Continuous input overload voltage 120% of nominal

  • Max. Short duration input voltage (300 msec) 2 x nominal voltage

  • Nominal input voltage burden < 0.5 VA per phase

  • Nominal input current 1A AC or 5A AC rms

  • Nominal input current burden < 0.1 VA

  • Max. Continuous input overload current 2 x nominal voltage

  • Max. Short duration input current (300 msec) 20 x nominal current

Auxiliary
  • Operating range 80 – 260 V AC/DC (+/- 10%) 45 – 66 Hz

  • Supply burden 6 VA

Accuracy
  • Voltage (V) < 0.2% IL3 Current L3

  • Current (A) < 0.2% IN Neutral I

  • Neutral current calculated (A) < 1.0% AVG I1 I2 I3 Average Current

  • Frequency (Hz) < 0.1 Hz DELTA I Current diff

  • Power factor (PF) 1% of unity I1 MAX I1 Max demand

  • Active power (W) +/- 0.2% of range I2 MAX I2 Max demand

  • Reactive power (VAr) +/- 0.2% of range I3 MAX I3 Max demand

  • Apparent power (VA) +/- 0.2% of range I1 AVG Average I1

  • Active energy (kWh) Class 0.2 (IEC 62053-21) I2 AVG Average I2

  • Reactive energy (kVArh) +/- 0.2% of range I3 AVG Average I3

  • Response time <200 msec P System power

Range
  • Voltage (V) 5% to 120% for nominal P2 Power L2

  • Current (A) 5% to 120% of nominal P3 Power L3

  • Frequency 45 – 65 Hz PMAX Max power

  • THD up to 31st harmonic PAVG Average power

Outputs
  • Analogue output (All programmable)

    • 0... +/- 1 mA

    • 0... +/- 5 mA

    • 0... +/- 10 mA

    • 0... +/- 20 mA

    • 4... +/- 20 mA

    • 0... +/- 1 V

    • 2... +/- 10 V

  • Pulse/alarm output relay User defined solid state relay

  • Contact rating 100 mA @ 250 V

  • Pulse duration 30 msec to 1000 msec

  • Alarm delay 0 – 120 secs

  • Alarm hysteresis 1 – 99%

  • Alarm type User Defined Solid State Relay

  • Communication protocol RS485 Modbus RTU

  • Type 2-wire half duplex

  • Baud rate 9600, 19200, 38400

Enclosure
  • Enclosure style DIN-rail mounting

  • Dimensions 100 x 79 x 118 mm

  • Material Polycarbonate to UL94-V0

  • Weight 0.42 kg

  • Terminals Shrouded screw-clamp 0.05 – 4 mm wire

Environment
  • Operating temperature -10°C to +55°C

  • Storage temperature -30°C to +70°C

  • Relative humidity 0 – 90% non-condensing

  • Shock 30 g in 3 planes

  • Vibration 10 Hz to 50 Hz

  • Dielectric voltage Withstand test 4 kV, 50 Hz for 1 minute between auxiliary/input/output

Input Parameters

Button
ID
Description
Voltage 

VL1
VL2
VL3
2VL12

VL23

VL31

AVG V12

V23 V31

AVG V1N

V2N V3N

DELTA V

DELTA VN

Volts L1 - N
Volts L2 - N
Volts L3 - N
Volts L1 - L2

Volts L2 - L3

Volts L3 - L1

Average Vvlt

- age (L-L)

Average Vvlt-

age (L-N)

Volts diff L-L

Volts diff L-N

Current

IL1 

IL2

IL3
IN

AVG I1 I2 I3
DELTA I

I1 MAX

I2 MAX

I3 MAX

I1 AVG

I2 AVG

I3 AVG

Current L1
Current L2
Current L3
Neutral I
Average Current
Current Diff

I1 Max demand

I2 Max demand

I3 Max demand

Average I1

Average I2

Average I3

Active Power

P

P1

P2

P3

PMAX

PAVG

System power
Power L1

Power L2

Power L3

Max power

Average Power

Reactive Power

Q
Q1

Q2

Q3

System VAr

Systme VAr L1

System VAr L2 Q3

System VAr L3

Apparent Power

S
S1

S2

S3

System VA

System VA L1

System VA L2

System VA L3

Power Factor

PF
PF1

PF2

PF3

PF AVG Average PF

PF1 PF L1

PF2 PF L2

PF3 PF L3

Angle

SYS ANGLE

ANGLE L1

ANGLE L2

ANGLE L3

System Angle

Phase Angle L1

Phase Angle L2

Phase Angle L3

THD

THDV1

THDV2

THDV3

THD I1

THD I2

THD I3

THD V1

THD V2

THDV3

THD V3

THD I2

THD I3

COSPHI

COSPHI 1

COSPHI 2

COSPHI 3

Displacememnt P.F

Displacememnt P.F

Displacememnt P.F

Specifications

Brand Crompton
Model 254
Input Range 1P2W 57.7-277VAC L-N, 0-1A or 0-5AAC, 3P3W 100-480VAC L-L, 0-1A or 0-5AAC, 3P4W 100-480VAC L-L (57.7-277V L-N), 0-1A or 0-5AAC
Input Frequency 60Hz, 50Hz
Output 0-1mADC, 0-10mADC, 0-20mADC, 4-20mADC, 0-5mADC, 0-1VDC, 0-10VDC
Aux. Power Supply Switching ~100-240VAC, 50/60Hz, Switching ~100-260VDC
Tariff Code 8543.20.0000
ECCN EAR99