Input Modules
- DC INPUT OPTIONS
DC Voltage Ranges
....
99.99mV,999.9mV.9.999V,99.99V,300VMax
DC Current Ranges
....
99.99µA,999.9µA,9.999mA,99.99mA,5.00A
Compliance Voltage
(Current Ranges)
.....
1V Standard, 1--mV Optional.
Attenuator ( Variable) ................10:1, (25
turn pot)
Input Impedance
(Current Ranges)....................>900K ohm
shunted by <20 pF
Voltage Accuracy..........................±0.02% Full Scale ±
1count
Current Accuracy.........................±0.05% Full Scale ± 1count
Tempco...........................................200 ppm/ºC
CMV to Analog grnd...................±1V peaj DC to 60Hz
CMV to AC Power grnd.............±500V peaj DC to 60Hz
CMRR.............................................80 db typical
wuth 1K unbalance
NMR....................................
....60 db typcal at 60 Hz
Overload Protection.............. ...200% F.S.
Analog Offset (Variable)........ ...±1V max. (25 turn pot)
Analog Ofsett Tempco........... ...700 ppm/ºC
Optional DC Voltage Range.......99.99mV min. to 300
Vdc max
Optional DC Current Ranges.. ..99.99µA \ V min. to 5.0 A max
Standard Suppressed Ranges. ..4-20mA, 1-5Vdc
- AC INPUT OPTIONS
Detector...................................Full
Wave average responding rms acaled
AC Voltage Ranges..................99.99mV,999.9mV.9.999V,99.99V,300VMax
AC Current Ranges.................99.99µA,9.999mA,99.99mA,999.99mA,5.000A
Compliance Voltage.
(Current Ranges)...............100mV
Standard, 1V Optional.
Attenuator (Variable)...............10:1, (25 turn pot)
Input Impedance
.(Voltage Ranges)...............>900K
ohm shunted by <20 pF
Accuracy................................±0.1% Full Scale ± 2 counts
Tempco...................................300 ppm ±0.1 count / ºC
Analog Offsett (Variable)..........±1V max. (25 turn pot)
Analog Offsett (Tempco)..........700 ppm/ºC
Frequency Response...............40 to 1K Hz
Overload Protection................200% F.S.
Optional AC Voltage Ranges....99.99mV
min. to 300 Vac max
Optional AC Current Ranges...99.99µA
min. to 5A ac max
- THERMOCOUPLE INPUT OPTIONS
Measurement Range: Depending on thermocouple type.
Type Range
Type Range
JC -194.4 to+50
TC -250 to + 388.8
JF -318 to+1382(999.9 @ 0.1 res) TF
-418 to + 732
KC -250 to+1361(999.9 @ 0.1 res) EC
-250 to+1000(999.9 @ 0.1 res)
KF -418 to+2482(999.9 @ 0.1 res) EF -418
to+1832(999.9 @ 0.1 res)
Open Thermocouple Indication: Selectable - Over-range or under-range
Linearization Method: Multi-segment linear interpolation
based on N.I.S.T Monograph 125
Accuracy: (Worst case, over operating range, after 20
Minute warm-up)
Conversion: ±.06% rdg ±3 LSD
Cold Junction Tempco: ±07 º/º internal
electronic ice point, or can be
Configured to use external reference junction.
Typical Performance:(at 25ºC) ±.03% rdg. ± 2 LSD
E Mail:---Sales @ IMS
(Instrument Meter Specialities)