Distributed By:
Instrument Meter Specialties
Phones: 800-926-3837....818-841-2417
FAX 818-926-3736

We accept Visa - MasterCard - American Express

IMSLogo.gif (3426 bytes)

TripLogo.JPG (1199 bytes)   Triplett  Model
630 Series Analog VOM

The Industry Standard for Laboratory, Bench and
Field Testing

  • Single Range Switch to help reduce chance of error
  • Diode overload protection and 2 fuse arrangement
  • Mirrored scale to reduce parrallax error
  • Decibel function for audio work
  • All ranges are fuse protected
  • Thermoset plastic case.


Model 630

Model 630
Features

28 Ranges and Functions
Glass meter window for added chemical resistance
Two input jacks to minimize error
AC Voltage frequency response to 40kHz typical
Resistance measurement of  30V / 100M on Rx100K
range for testing insulation

Functions
DC Voltage
Ranges: 0.3 (16,667 ohms / Volt) 3,12,.60,300,600
              (20k ohms / Volt)
Accuracy: ±1.5% of full scale
AC Voltage
Ranges: 3,12,.60,300,600 (5k ohms / Volt)
Accuracy: ± 3% of full scale
DC Current (Milliamperes)
Ranges:   0.06, 1.2, 12, 120
Burden Voltage: 300mV
Accuracy: ±1.5% of full scale
Resistance
Ranges:  1k, 10k, 100k, 1M, 100M Ohms
Center Scale: 4.4 ohms on lowest range
Accuracy: ±1.5% of  Scale Length

Decibels:-20dBm to +57dBm  (1mW, 600 ohms)
Catalog No. 3030
  Model 630


Models:
630-PL
630-PLK

DISCONTINUED

 

Model 630-PL & 630-PLK
Features
DISCONTINUED
28 Ranges and Functions
AC Voltage frequency response to 40kHz typical
Output Voltage measurement ( DC block)
Current measurement to10 Amp (no external shunt)
Overload relay (630-PLK)
Polarity reversing switch
Range doubling switch
Large plastic window for durability and easy viewing
Resistance measurement of  30V / 100M on Rx100K
range for testing insulation

Functions
DC Voltage
Ranges: 0.25 (10k ohms / Volt) 2.5,10,.50,250,1000
              (20k ohms / Volt)
Accuracy: ±1.5% of full scale
AC Voltage
Ranges: 3,10,.50,250,1000 (5k ohms / Volt)
Accuracy: ± 3% of full scale
AC Output Voltage Measurement (DC Block)
Ranges: 3, 10, 50, 250 (5k ohms / Volt)
DC Current
Ranges:   100µA, 10mA, 100mA, 1A, 10A
Burden Voltage: 1V
Accuracy: ±1.5% of full scale

Resistance
Ranges:  1k, 10k,  1M, 100M Ohms
Center Scale: 4.4 ohms on lowest range
Accuracy: ±1.5% of  Scale Length

Decibels:-20dBm to +49dBm  (0dBm at 1mW on a  600                  ohms line)
Catalog No. 3050
  Model 630-PL
Catalog No. 3055  Model 630-PLK (With Overload Relay

DISCONTINUED

The Triplett Model 630-PLK as safety designed .   The overload
protectionrelay will "fire" when the input voltage reaches 4 to 6
times the full scale reading and will remain open until manually
reset.

Model 630 Series General Specifications
Meter Movement 50µA (5µA for 630-NS) 4½" Taut Band, Bar-ring, Diode protected, 630-NA & 630-NS have temperature compensation
Dimensions 3 11/32" x 5.5" x 7.5" (85mm x 140mm x 190mm)
Batteries (1)30V NEDA #210 and (1)1.5V NEDA #13F except 630-NS
which uses (1)1 .5V  NEDA #15A and (1)1.5V D-Cell NEDA 13F
Weight 5 Lbs. (2.25 kg.)
Accessories 48" Safety Test Leads, screw-on insulated alligator clips,
batteries, spare fuse, and instruction manual
Warranty Three (3) Years . One (1) Year on Calibration

Click for Test Lead Specifications

Click for Model 10 Series Attachment Leads


Back to Instrument Meter Specialties, Inc. Home Page

Click for Test Equipment Price List

Back to Triplett Test Equipment Contents

Phones: 800-926-3837....818-841-2417
FAX 818-926-3736



We accept Visa - MasterCard - American Express 


(All Prices are subject to change without notice)

Copyright © 1998-2001 Instrument Meter Specialists