Distributed By:
Instrument Meter Specialties, Inc
Phones: 800-926-3837....818-841-2417... FAX 818-841-2379
  We accept:
 Visa - MasterCard - American Express

TES-3050 AC/DC True RMS Digital Clamp-on
IEC 1010      CAT. III 600V POLLUTION 2

Features:

True RMS reading 1000A
• Auto-Zero for DCA
• Autoranging on V, ?, A, Hz
• Bar-Graph indication
• 3-3/4 Digital LCD with Bar-graph
• Autoranging on Volt, Ohm, Current, 
  Frequency measurements
• Auto-power off
• Data Hold mode
• MAX/MIN Hold mode
• Zero Adjustment/Relative Reading
• Peak Hold Mode (only ACV and ACA range)
• Two year warranty

Specifications for TES-3050 AC/DC

Numerical Display: 3-3/4 digit liquid
crystal display (LCD) maximum reading 3999
Over Range Indication: LCD will show in “OL”
Sampling Rate: 20 times/sec (Bar-Graph) 
2 times/sec (Digital Display)
Power Source: One 006p 9V or IEC 6F22 or NEDA 1604 Battery
Battery Life: 30hr approx.
Auto-power off time: Approx. 30 minutes
Operating Temperature 0°C to 40°C 
and Humidity: (32°F to 104°F) below 80% RH
Storage Temperature -10°C to 60°C 
and Humidity: (14°F to 140°F) below 70% RH.
Dimensions: 239(L) x 66(W) x 34(H) mm
Weight: Approx. 365g
Jaw Opening: 46mm

 

 


A: General Measurement
DC Voltage (Autorange & Manual)
Range: 400mV/4V/40V/400V/600V
Resolution: 0.1mV/0.001V/0.01V/0.1V/1V
Accuracy: ± 0.75% rdg + 2 dgts
Input Impedance Ohms::1000M/ 11M/ 10M
Overload Protection: 660Vrms
DC Current (Autorange & Manual)
Range: 400A/1000A
Resolution: 0.1mA/1A
Accuracy: ± 2% rdg + 25 dgts
Overload Protection: 1100A
AC Voltage (Autorange & Manual)
Range: 4V/40V/400V/600V
Resolution: 0.001V/0.01V/0.1V/1V
Accuracy: ± 1.2% rdg + 5 dgts/± 1.5% rdg + 5 dgts
Input Impedance: = 11M?/ 10M?
Overload Protection: 660Vrms
Frequency (Hz) (Autorange only)
Range: 100Hz/1KHz/10KHz/100KHz/1000KHz
Resolution: 0.01Hz/0.1Hz/0.001KHz/0.01KHz/0.1KHz
Accuracy: ± 0.5 rdg + 2 dgts
Sensitivity: 100mV or 1A
Overload Protection: 1100A/600Vrms
Resistance (Ohms) (Autorange & Manual)
Range: 400/4K/40K/400K/4M/40M
Resolution: 0.1?/0.001K/0.01K/0.1K/
0.001M?/0.01M?
Accuracy: ± 1% rdg + 2 dgts/± 1.5% rdg + 2 dgts
Open Circuit Voltage: <0.5VDC
Overload Protection: 600Vrms
Audible continuity
Range:
Continuity Beeper: <40?
Open Circuit Voltage: <0.5V
Overload Protection: 
600Vrms
Diode Test
Range:
Resolution: 0.001V
Accuracy: ± 1% rdg + 2 dgts
Overload Protection: 
600Vrms
B: Peak Hold
Measurement
AC Voltage 
(Autorange & Manual)
Range:
4V/40V/400V/600V
Resolution:
0.001V/0.01V/0.1V/1V
Accuracy (50Hz~60Hz): ± 2,5% rdg + 5 dgts
Input Impedance: 11M?/ 10M?
Overload Protection: DC 1100V/AC 800V
AC Current (Autorange & Manual)
Range: 400A/1000A
Resolution: 0.1A/1A
Accuracy: ± 2.5% rdg + 5 dgts
Overload Protection: 1100A


Back to MTP  Price List

Copyright ©2000 Instrument Meter Specialties, Inc.
         

2108 B West Magnolia Blvd
Burbank, CA  91506

Phone: 800-926-3837           FAX: 818-841-2379