Distributed By:
Instrument Meter Specialties, Inc.
Phones: 800-926-3837....818-841-2417
FAX 818-841-2379

We accept:  Visa - MasterCard - American Express

Tes-1336 Digital Datalogging Light Meter (RS232)

 

Features:
• Spectrum of photo sensor meets       C.I.E. Standard Illuminant A
• 8000 records data logging capacity
• Lux/Fc selection
• Data-Hold function
• Standard Illuminant A
• RS-232 interface (software              included)
• Measurement of luminous intensity (PC Software) 

Specifications for TES-1336

Specifications JIS C1609-1993 ~                         CNS 5119-1998 A
Measuring Range: 20/200/2000/20000 Lux 20, 200/2000/20000, Fc
Luminous intensity (cd): 
Intensity = illuminance x (length)2, Length { feet (Fc) meter (Lux)
Resolution: 0.01 Lux
Accuracy: ± 3% rdg ± 0.5% f.s.          (Calibrated to standard 
incandescent lamp, 2856K)
Over-range display: “OL”
Record (Data logging): 8000 Point Data logger
Sensor: Silicon photo diode
Sensor lead length: 150cm (approx.)
Sensor probe: 100(L) x 60(W) x 27(H) mm
Main instrument: 145(L) x 72(W) x 31(H) mm/235g (approx.)
Power source: One 9V battery
Battery life: 50hrs (approx.)
Operating/Storage Condition: 0°C~40°C (32°F~104°F) 
below 80% RH -10°C~60°C (14°F~140°F) below 70% RH
Accessories: 
Carrying case ~ 9V battery ~     Instruction Manual ~ Software (Win 95) ~ RS-232 cable ~
~ 9 to 25 Pin Gender Changer

 Return to MTP Price List 
 
Instrument Meter Specialties, Inc. © 2000
2108 B West Magnolia Blvd
Burbank, CA  91506

Phone: 800-926-3837           FAX: 818-841-2379