Distributed By: Instrument Meter Specialties |
Ruggedized-Sealed Series Models 235 (2½")355(3½")455(4½") |
| Gasket-sealed metal cases Great in severe environments Taut band suspension standard for sensitive ranges Standard indication accuracy of ±3% for AC Wide selection of ranges Customized scales available Mirrored scales available on Model 455 Special pointers and other options available |
|
| Ruggedized-Sealed Panel Meters are designed
and built to function in severe environments. The meter movement is securely
anchored in a gasket-sealed metal case to provide protection against severe shock, salt
spray, fungus, and corrosive chemicals.The meter conforms to the gasket sealing
requirements of Mil-M10204-C specifications. The rugged-sealed panel meters are available
in three sizes as shown above.These panel meters are identical in appearance and in
dimensions with the other LFE/api ruggedized-sealed instruments
(pyrometers and meter relays) . This interchangeability facilitates panel designing
and functional upgrading. The Ruggedized-Sealed Panel Meters use d'Arsonval meter mechanisms. The meters are furnished with taut band suspensions as standard in the sensitive ranges from 0-5µA to 100µA and 0-5mV to 0-25mV. Taut band suspensions may be specified for other ranges as required. The higher ranges are normally furnished as povot-and-jewel mechanisms. Taut bands provide the advantage of friction-free measurements for the ultimate in accuracy. Taut band also allow the meter to respond to extremely small signals, extending the application of ruggedized-sealed panel meters to areas of sensitivity not previous possible. Additionally, taut band meters offer increased resistance to shock and vibrations over older, pivot-and-jewel designs. Because severe vibration can cause momentary erratic readings on taut band meters, Triplett can provide specially damped meters which are free of this problem, but have relatively slow response time. LFE/api by Triplett Ruggedized-Sealed Panel Meters have a one year warranty backed by IMS - Instrument Meter Specialities . |
|
Round Meter Model 1235 Specifications |
||||||
Specifications |
DC Ranges | AC Ranges (Rectifier Type) | Pyrometer | |||
| Current | Voltage | Current | Voltage | |||
| Accuracy | ±2% |
±2% |
±3% | ±3% | ±2% |
|
| Tracking | Optional | Optional | Optional | Optional | N/A | |
| Balance | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Repeatability | Taut Band Mechanism |
< ¼% | < ¼% | < ¼% | < ¼% | < ¼% |
Pivot & Jewel |
2% | 2% | 2% | 2% | N/A | |
| Resistance Tolerance | ±20% | ±5% | ----- | < 10V ±20% > 10V ±5% |
N/A | |
| Overload Capacity |
1 Second | 1000% | < 100V 1000% > 100V 200% |
150% | 150% | N/A |
| Continuous | 150% | 120% | 150% | 120% | N/A | |
| Calibration Frequency | -------- | -------- | 60 Hz | 60 Hz | N/A | |
| Overshoot (maximum) | 20% | 20% | 20% | 20% | N/A | |
| Response Time (maximum) |
Sensitivity>50µa | 1.5 sec | 1.5 sec | 1.5 sec | 1.5 sec | N/A |
| Sensitivity<50µa | 3 sec | 3 sec | 3 sec | 3 sec | N/A | |
Effects of shock, vibration, humidity and temperaure are equal to or
better than ANSI C39.1-1981Safety (dielectric test , leakage and other hazards)
instruments are equal to or better than ANSI C39.5-1974. The above tolerance
limits apply to the standard ranges listed in this bulletin. Special
instrumants may vary from these limits.Rated circuit to ground
voltage = 800 Vrms (1100 Peak)
| DC Ranges | Process Ranges | AC Ranges | |||
| DC Microamperes | 5 to 1000 | DC Millamperes | 1-5, 4-20, 10-50 | AC Microamperes | 100 to 1000 |
| DC Milliamperes | 1 to 1000 | DC Volts | 1-5, 0-10 | AC Milliamperes | 1 to 1000 |
| DC Amperes | 1 to 9 |
|
AC Amperes | 1 to 50 | |
| DC Millivolts | 5 to1000 | AC Millivolts | 250 & 500 | ||
| DC Volts | 1 to 500 | AC Volts | 1 to 500 | ||
| Rugged-Sealed Meter Dimensions | ||||
| Model | Flange Diameter |
Barrel Diameter |
Depth | Phones: 800-926-3837....818-841-2417.......FAX 818-841-2379
|
| 255 (2 ½") | 2.80 | 2.155 | 1.97 | |
| 355 (3 ½") | 3.58 | 2.62 | 2.16 | |
| 455( 4 ½") | 4.56 | 3.9 | 2.05 | |
Jump to IMS (Instrument Meter Specialties) Home Page)
Copyright © 1998-2001 Instrument Meter Specialties