Mechanical Relay Connections

Mechanichal Relay Gound Fault Sensors

Applications

Personnel Protection (typically 5mA) Senses low fault currents and alarms to shut power before injury occurs.

Equipment Protection (typically 30mA) When personal protection is not an issue, select a higher setpoint to protect equipment or product.

Regulatory Approval

Meet requirements by industry groups and governments for Ground Fault Protection.

Ground Fault Sensor Circuit Example

Features

Dimensions

Broad Range of Options to Match Application Needs:

— Choice of NO/NC solid-state switch and mechanical relay outputs.

— Normally energized or normally de-energized contacts.

— Latching outputs for controlling contactors; auto-reset option for control of shunt trip breakers.

— Noise-immune option for use in EMI/RFI sensitive environments.

Setpoint Options Maximize Ease-of-Use:

— Field-selectable 5mA, 10mA or 30mA setpoints (AG3 “Tri-set” model only) makes user-adjustable setpoint fast and convenient.

— Single, factory-adjusted setpoint can be fixed from 5mA to 950mA when ordering.

Compatible with Standard Equipment

— Applicable on most 1Φ and 3Φ systems.

— Ideal for use with shunt trip breakers or contactors.

— Magnetically isolated from monitored circuit and control power.

Agency Approved

UL, CUL and CE acceptance worldwide.

Output Table

Normally Energized Models (–ENE Option)

Protection from faults

and loss of control power

                                     Control Power Applied

                  No Power             No Fault             Fault

N.C.             Closed                  OPEN              Closed

N.O.             OPEN                  Closed              OPEN

Normally De-energized Models (–DEN Option)

Protection from faults only when control power is applied

                                     Control Power Applied

                  No Power              No Fault              Fault

N.C.             Closed                 CLOSED            OPEN

N.O.              OPEN                  OPEN              Closed

Latching Models (-LA Option)

Latching models initially power up in the Reset (Normal) position. If there is a fault or the test button is pressed, the output switches and is latched. The output will

remain latched after the fault is cleared, even if control power is removed. To reset the output, apply a momentary contact across the “Reset” terminals (5-6).

Specifications

Dimensions

Setpoint Range

“Single-Set” Models Factory adjusted and sealed

AG1: 5–100mA, specify when ordering

AG2: 80–950mA, specify when ordering

“Tri-Set” Models 5, 10 & 30mA jumper select

Output

Auto Reset: SPDT Relay, 1.0A @ 125VAC, 2A @ 30VDC

Latching: SPST Relay, 1.0A @ 125VAC, 2A @ 30VDC

Response Time

200 ms @ 5% above setpoint

60 ms @ 50% above setpoint

15 ms @ 500% above setpoint

Isolation Voltage Up to 1,250VAC (monitored circuit)

Frequency Range 50–400Hz (monitored circuit)

Noise Immunity Option

Shielded from external EMI/RFI interference.

Power supply noise filtering.

Sensing Aperture 0.75" (19.1mm) dia., up to 4" (100mm) dia. available, consult factory.

Power Supply

120VAC, operates from 55-110% of nominal voltage

24VAC & 24VDC, operates +/–10%

Case UL 94V-O Flammability Rated

Environmental 5 to 158°F (–15 to 70°C), 0-95% RH, non-condensing

Safety UL 1053, Class 1 Recognized, CE*

*UL and CE recognition is pending.

Ordering Information

Example: AG1-NOR1-120-LA-005

Ground fault sensor with normally open SPST Relay output, latching, 120VAC power supply, 5mA setpoint, without optional noise immunity.

Mechanical Relay Ordering Information

Dimensions

Mechanichal Relay Case Diagram